ZONE PLATE TEST CHAR品T
- Introduction
- Product Software
Y63P ZONE PLATE TEST CHART
REFLECTANCE
Checking resolution characteristics and cross color interferences of TV cameras and TV transmission systems
DATA
On a neutral surrounding area with a density of D ~ 0.4 four large zone plates are arranged. Each zone plate consists of concentric
circular rings, with their width and distances decreasing outwards. The geometry of the circular rings causes the space frequencies
of the zone plate to increase linearly with the distance from the circle center. At the outer edge of the circular rings we have 575
lines per picture height and thus a spatial frequency of 575/2 = 287.5 periods or line pairs per picture height. In our 625 line TV
system (575 active lines, 52 µs active line duration, aspect ratio 4:3) this corresponds to a frequency of 7.4 MHz in horizontal direction.
According to the scanning theorem horizontal lines of 287.5 periods per picture height can just or just not be resolved (Nyquist frequency)
by a 625 line TV system.
In the picture center there is a small zone plate with the spatial frequencies being twice as high as those of the large zone plates. At the
outer edge of this central circular field we have a spatial frequency of 1150/2=575 periods or line pairs per picture height. This corresponds
to a frequency of 14.8 MHz in horizontal direction.
The left and right edges of the picture show one white and one black vertical bar each with densities of D~0.1 resp. D~1.7. These bars serve
as a reference when measuring the resolution by oscilloscope as well as for level adjustment.
UTILISATION
The Zone Plate method has proved worthwhile especially for subjective comparison measurement at the TV screen. For objective measurement
it is less suitable. Therefore it is not an in service test method. The Zone Plate method is rather an important aid for developing new systems and
devices. And it also can be recommended for comparison during approval measurements.
With the aid of the Zone Plate method the following characteristics of TV cameras can be determined:
• resolution in horizontal, vertical and diagonal direction
• correlation between the resolution and the scanning spot
• effects of horizontal and vertical aperture corrections
• astigmatism of the camera scanning beam (tube cameras)
• effects of interferences between the zone plates and the television line resp. the shadow mask structure of color picture tubes
• effects of PAL coding (e.g. cross color)
• reaction during horizontal and vertical movement of the camera (or the test chart)
• dynamic resolution
• temporal interferences (e.g. due to cross color)
The use of the Zone Plate method is particularly recommended for test objects where the television signal is filtered multidimensonally
(horizontally, vertically and temporally). These can be aperture correctors of TV cameras or standard PAL-decoders (with line delays)
and combifilter PAL-decoders. Zone Plates also allow to determine the effects of pre- and post-filtering of MAC-systems (with
line-sequential color transmission). Particularly useful is the optical Zone Plate Test Chart for checking CCD cameras.
When measuring resolution it has to be noted that with the optical Zone Plate Test Chart the density in the circular fields changes
rapidly. This means that besides the fundamental wave of the space frequencies there are also harmonic waves. When scanning
the zone plates with the TV line system those harmonic waves which surpass the Nyquist frequency may cause interference patterns
in the television picture (the so-called aliasing components) which again show zone plates. These interference zone plates result
from interference between the Zone Plates of the test chart and the scanning television line system. Due to the interlaced scanning the
interference zone plates are not static but flicker in a 25 Hz rhythm.
When working with cameras with electron-optical scanning (tube cameras) these interferences are usually very low since the scanning
electron beam has a distinct low-pass filter characteristic due to its three-dimensional extension. This leads to a pre-filtering of picture
shot. The reaction with CCD cameras is different. Due to the clearly defined geometric structure of the CCD elements in horizontal and
vertical direction noticeable interference patterns both horizontally and vertically may occur (see picture).
During PAL-transmission ther are in addition cross-color interferences through cross-talking of light density components in the
chromatic chain. During reproduction of a PAL-coded Zone Plate Test Chart on a color monitor the cross-color interferences can be
seen as small pulsating colored zone plates with their centers lying in horizontal direction at the PAL color sub-carrier frequency 4.43
MHz. When the PAL decoder works with comb filters the cross-color interferences are generally less significant in stationary pictures
than in moving pictures (i.e. when camera or test chart is moved).
In fact the PAL coder and especially the PAL decoder are primarily responsible for the cross color interferences, but even a too “sharp”
aperture correction may increase the cross color considerably. In order to locate the cause of cross color interferences it is recommended
to work not only with the optical Zone Plate Test Chart (and the camera) but also with an electronic zone plate generator.
In general it is recommended to use a zone plate generator whenever test object has electric inputs. These are besides transmission devices
like a aperture correctors, PAL coders and decoders also monitors. Compared to the optical Zone Plate Test Chart zone plate generators
have the advantage that the output signals of the zone plate can either be generated in a square shape or as continuous sinusoidal transitions.
Dynamising the Zone Plate can also be effected easily in an electronic way.
News
- 2014-06-26 3nh Products Have Got CE Certificat ...
- 2015-05-08 PANTONE CU Color Card (Electronic E ...
- 2017-07-08 How to use SFR resolution test char ...
- 2014-06-12 ISO 12233 RESOLUTION TEST CHART
- 2014-06-26 3nh ROHS Certificate
- 2014-06-12 Pantone TPX 2012 (175 New Colors)
- 2014-06-12 Colorimeters Versus Spectrophotomet ...
- 2014-06-26 3nh TUV Certificate